Content text 3 iron.pdf
Test Method Conformity Assurance Dammam – Electrical Lab Product iron Issue date 01/04/2024 Test method # TMD01003 Revision 01 Reference standered SASO GSO IEC 60335-2-3, SASO GSO IEC60335-1 Revision date 01/04/2024 Result /النتيجة Name of the test/ االختبار اسم البند رقمClause No. Checking Frequency MOCI_D_267A Checking country of origin MOCI_D_267B Checking for Rated Voltage MOCI_D_267B الوسم و االرشادات and Marking instructions 7 القدرة و التيار and input Power current 10 االرتفاع في الحرارة – rise Temperature Heating 11 تيار التسريب و المتانة الكهربائية electric and current Leakage strength 16 19 التشغيل غير الطبيعي operation Abnormal 21 المتانة الميكانيكية strength Mechanical (2203SASO(4.3 القابس : الشكل و المقاسات و المقننات Plug
Test Method Conformity Assurance Dammam – Electrical Lab Product iron Issue date 01/04/2024 Test method # TMD01003 Revision 01 Reference standered SASO GSO IEC 60335-2-3, SASO GSO IEC60335-1 Revision date 01/04/2024 7 Marking 7.1 Appliances shall be marked with the: rated voltage or rated voltage range in volts symbol for nature of supply, unless the rated frequency is marked; Appliances shall be marked with their rated power input name, trade mark or identification mark of the manufacturer or responsible vendor model or type reference symbol 5172 of IEC 60417, for class II appliances only IP number according to degree of protection against ingress of water, other than IPX0 7.1 addition Separate stands shall be marked with – name, trademark or identification mark of the manufacturer or responsible vendor; – Model or type reference of the stand. Stands of cordless irons shall be marked with their – rated voltage or rated voltage range; – rated power input. 7.2 Stationary appliances for multiple supply shall be marked with the substance of the following: Warning: Before obtaining access to terminals, all supply circuits must be disconnected. This warning shall be placed in the vicinity of the terminal cover. 7.3 Appliances having a range of rated values and which can be operated without adjustment through out the range shall be marked with the lower and upper limits of the range separated by a hyphen.
Test Method Conformity Assurance Dammam – Electrical Lab Product iron Issue date 01/04/2024 Test method # TMD01003 Revision 01 Reference standered SASO GSO IEC 60335-2-3, SASO GSO IEC60335-1 Revision date 01/04/2024 Appliances having different rated values and which have to be adjusted for use at a particular value by the user or installer shall be marked with the different values separated by an oblique stroke. 7.4 If the appliance can be adjusted for different rated voltages, the voltage to which the appliance is adjusted shall be clearly discernible. 7.5 For appliances marked with more than one rated voltage or with one or more rated voltage ranges, the rated power input or rated current for each of these voltages or ranges shall be marked 7.6 Correct use of symbols 7.7 Appliances to be connected to more than two supply conductors and appliances for multiple supplies shall have a connection diagram fixed to them, unless the correct mode of connection is obvious. 7.8 Terminals used for connection to the supply mains shall be indicated as follows: Terminals intended exclusively for the neutral conductor shall be indicated by letter N Protective earthing terminals shall be indicated by the symbol 5019 of IEC 60417. 7.9 Unless it is obviously unnecessary, switches which may give rise to a hazard when operated shall be marked or placed so as to indicate clearly which part of the appliance they control. 7.10 Indication of the different positions of switches on stationary appliances and the different positions of controls on all appliances shall be indicated by figures, letters or other visual means If figures are used for indicating the different positions, the off position shall be indicated by the figure 0 and the position for a higher value, such as output, input, speed or cooling effect, shall be indicated by a higher figure. 7.11 Controls intended to be adjusted during installation or in normal use shall be provided with an indication for the direction of adjustment 7.12 Instructions for use shall be provided with the appliance so that the appliance can be used safely
Test Method Conformity Assurance Dammam – Electrical Lab Product iron Issue date 01/04/2024 Test method # TMD01003 Revision 01 Reference standered SASO GSO IEC 60335-2-3, SASO GSO IEC60335-1 Revision date 01/04/2024 This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. 7.12 addition the iron must not be left unattended while it is connected to the supply mains; the plug must be removed from the socket-outlet before the water reservoir is filled with water (for steam irons and irons incorporating means for spraying water); the filling aperture must not be opened during use. Instructions for the safe refilling of the water reservoir shall be given (for pressurized steam irons); the iron must only be used with the stand provided (for cordless irons); the iron is not intended for regular use (for travel irons); the iron must be used and rested on a stable surface; when placing the iron on its stand, ensure that the surface on which the stand is placed is stable; the iron is not to be used if it has been dropped, if there are visible signs of damage or if it is leaking. 7.12.1 If it is necessary to take precautions during installation of the appliance, appropriate details shall be given. 7.12.2 If a stationary appliance is not fitted with a supply cord and a plug, or with other means for disconnection from the supply mains 7.12.3 If the insulation of the fixed wiring supplying an appliance for permanent connection to the supply mains can come into contact with parts having temperature rise exceeding 50 K during the test of clause 11 7.12.4 Instructions for built-in appliances 7.12.5 Instructions for appliances with type X attachment having a specially prepared cord Instructions for appliances with type Y attachment