Test Method Conformity Assurance Dammam – Electrical Lab Product Commercial Electric Deep Fryer Issue date 01/04/2024 Test method # TMD01037 Revision 01 Reference standered SASO GSO IEC 60335-1 and SASO GSO IEC 60335-2-37 Revision date 01/04/2024 Result /النتيجة Name of the test/ االختبار اسم البند رقمClause No. Checking Frequency MOCI_D_267A Checking country of origin MOCI_D_267B Checking for Rated Voltage MOCI_D_267B 7 الوسم و االرشادات instructions and Marking الحماية من الوصول الى االجزاء المكهربة to access against Protection live parts 8 Power input and current التيار و القدرة 10 11 االرتفاع في الحرارة Heating – rise Temperature تيار التسريب و المتانة الكهربائية current Leakage and electric strength 13 19 التشغيل غير الطبيعي operation Abnormal 21 المتانة الميكانيكية strength Mechanical
Test Method Conformity Assurance Dammam – Electrical Lab Product Commercial Electric Deep Fryer Issue date 01/04/2024 Test method # TMD01037 Revision 01 Reference standered SASO GSO IEC 60335-1 and SASO GSO IEC 60335-2-37 Revision date 01/04/2024 7 Markings and Instructions 7.1 Appliances shall be marked with the: – rated voltage or rated voltage range in volts – symbol for nature of supply, unless the rated frequency is marked; – rated power input in watts or rated current in amperes; – name, trade mark or identification mark of the manufacturer or responsible vendor – model or type reference symbol 5172 of IEC 60417, for class II appliances only IP number according to degree of protection against ingress of water, other than IPX0 Deep fat fryers shall be marked with the maximum oil level. They shall also be marked with the minimum oil level, unless they can be used as frying pans. Appliances intended to be partially immersed in water for cleaning shall be marked with the maximum level of immersion and with the substance of the following: Do not immerse beyond this level. 7.2 Stationary appliances for multiple supply shall be marked with the substance of the following: Warning: Before obtaining access to terminals, all supply circuits must be disconnected This warning shall be placed in the vicinity of the terminal cover
Test Method Conformity Assurance Dammam – Electrical Lab Product Commercial Electric Deep Fryer Issue date 01/04/2024 Test method # TMD01037 Revision 01 Reference standered SASO GSO IEC 60335-1 and SASO GSO IEC 60335-2-37 Revision date 01/04/2024 7.3 Appliances having a range of rated values and which can be operated without adjustment throughout the range shall be marked with the lower and upper limits of the range separated by a hyphen. Appliances having different rated values and which have to be adjusted for use at a particular value by the user or installer shall be marked with the different values separated by an oblique stroke. 7.4 If the appliance can be adjusted for different rated voltages, the voltage to which the appliance is adjusted shall be clearly discernible. 7.5 For appliances marked with more than one rated voltage or with one or more rated voltage ranges, the rated power input or rated current for each of these voltages or ranges shall be marked. The upper and lower limits of the rated power input or rated current shall be marked on the appliance so that the relation between input and voltage is clear. 7.6 Correct use of symbols Add the following symbol: Ipotentiality (ref. 417 – IEC-5021-a) 7.7 Appliances to be connected to more than two supply conductors and appliances for multiple supply shall have a connection diagram fixed to them, unless the correct mode of connection is obvious. 7.8 Except for type Z attachment, terminals used for connection to the supply mains shall be indicated as follows: – Terminals intended exclusively for the neutral conductor shall be indicated by the letter N; – Protective earthing terminals shall be indicated by symbol 5019 of IEC 60417. These indications shall not be placed on screws, removable washers or other parts which can be removed when conductors are being connected. 7.9 Unless it is obviously unnecessary, switches which may give rise to a hazard when operated shall be marked or placed so as to indicate clearly which part of the appliance they control
Test Method Conformity Assurance Dammam – Electrical Lab Product Commercial Electric Deep Fryer Issue date 01/04/2024 Test method # TMD01037 Revision 01 Reference standered SASO GSO IEC 60335-1 and SASO GSO IEC 60335-2-37 Revision date 01/04/2024 7.10 The different positions of switches on stationary appliances and the different positions of controls on all appliances shall be indicated by figures, letters or other visual means. If figures are used for indicating the different positions, the off position shall be indicated by the figure 0 and the position for a higher value, such as output, input, speed or cooling effect, shall be indicated by a higher figure. The figure 0 shall not be used for any other indication unless it is positioned and associated with other numbers so that it does not give rise to confusion with the indication of the off position. 7.11 Controls intended to be adjusted during installation or in normal use shall be provided with an indication for the direction of adjustment. 7.12 Instructions for use shall be provided with the appliance so that the appliance can be used safely 7.14 The markings required by the standard shall be clearly legible and durable 7.15 The markings specified in 7.1 to 7.5 shall be on a main part of the appliance Markings on the appliance shall be clearly discernible from the outside of the appliance but if necessary after removal of a cover 7.103 Appliances shall be marked with the minimum and maximum oil levels. Compliance is checked by inspection 8 Protection against access to live parts 8.1.1 Test probe B of IEC 61032 is applied without appreciable force, the appliance being in every possible position 8.1.2 Test probe 13 of IEC 61032 is applied without appreciable force through openings in class 0 appliances, class II appliances and class II constructions, except for those giving access to lamp caps and live parts in socket-outlets.

Tài liệu liên quan

x
Báo cáo lỗi download
Nội dung báo cáo



Chất lượng file Download bị lỗi:
Họ tên:
Email:
Bình luận
Trong quá trình tải gặp lỗi, sự cố,.. hoặc có thắc mắc gì vui lòng để lại bình luận dưới đây. Xin cảm ơn.